                                        INSTRUMENT CONTROL PARAMETERS:    US12274A05
                                        --------------------------------------------

   C:\MSDCHEM\1\METHODS\FSKN_100\FCKN32Y5.M
      Thu Apr 03 16:23:59 2014

Control Information
------- -----------

Sample Inlet      :  GC
Injection Source  :  GC ALS
Mass Spectrometer :  Enabled


 No Sample Prep method has been assigned to this method.

Oven
Equilibration Time                           1 min
Max Temperature                              300 degrees C
Slow Fan                                     Disabled
Oven Program                                 On
    280 C for 15 min
    then 10 C/min to 280 C for 10 min
Run Time                                     25 min
Cryo                                         Off

Front Injector
Syringe Size                                 10 ?L
Injection Volume                             1 ?L
Solvent A Washes (PreInj)                    0
Solvent A Washes (PostInj)                   10
Solvent A Volume                             8 ?L
Solvent B Washes (PreInj)                    0
Solvent B Washes (PostInj)                   0
Solvent B Volume                             8 ?L
Sample Washes                                1
Sample Wash Volume                           8 ?L
Sample Pumps                                 5
Dwell Time (PreInj)                          0 min
Dwell Time (PostInj)                         0 min
Solvent Wash Draw Speed                      300 ?L/min
Solvent Wash Dispense Speed                  6000 ?L/min
Sample Wash Draw Speed                       300 ?L/min
Sample Wash Dispense Speed                   6000 ?L/min
Injection Dispense Speed                     6000 ?L/min
Viscosity Delay                              0 sec
Sample Depth                                 2 mm
Injection Type                               Standard
L1 Airgap                                    0,2 ?L

Sample Overlap
Sample overlap is not enabled

Front SS Inlet He
Mode                                         Split
Heater                                       On    300 C
Pressure                                     On    20,406 psi
Total Flow                                   On    14 mL/min
Septum Purge Flow                            On    3 mL/min
Gas Saver                                    Off
Split Ratio                                  10 :1
Split Flow                                   10 mL/min

Thermal Aux 2 (MSD Transfer Line)
Heater                                       On
Temperature Program                          On
    290 C for 0 min
Run Time                                     25 min

Column #1
Agilent 19091S-433: 2107.39949
HP-5MS  5% Phenyl Methyl Silox
325 C: 30 m x 250 ?m x 0,25 ?m
In: Front SS Inlet He
Out: Vacuum

(Initial)                                    280 C
Pressure                                     20,406 psi
Flow                                         1 mL/min
Average Velocity                             39,718 cm/sec
Holdup Time                                  1,2589 min
Flow Program                                 On
    1 mL/min for 0 min
Run Time                                     25 min

Aux EPC 1 N2
Pressure Program                             Off
    10 psi for 0 min
Run Time                                     25 min

Aux EPC 2 N2
Pressure Program                             Off
    10 psi for 0 min
Run Time                                     25 min

Aux EPC 3 N2
Pressure Program                             Off
    10 psi for 0 min
Run Time                                     25 min

Signals
Signal #1: Test Plot                         Save Off
                                             50 Hz

Signal #2: Test Plot                         Save Off
                                             50 Hz

Signal #3: Test Plot                         Save Off
                                             50 Hz

Signal #4: Test Plot                         Save Off
                                             50 Hz

                                MS ACQUISITION PARAMETERS


General Information
------- -----------

Tune File                : atune.u
Acquistion Mode          : Scan


MS Information
-- -----------

Solvent Delay            : 5.00 min

EMV Mode                 : Gain Factor
Gain Factor              : 1.00
Resulting EM Voltage     : 1259

[Scan Parameters]

Low Mass                 : 35.0
High Mass                : 550.0
Threshold                : 150
Sample #                 : 2       A/D Samples    4
Plot 2 low mass          : 50.0
Plot 2 high mass         : 550.0

[MSZones]

MS Source                : 230 C   maximum 250 C
MS Quad                  : 150 C   maximum 200 C


                             END OF MS ACQUISITION PARAMETERS


                              TUNE PARAMETERS for SN: US12274A05
                        -----------------------------

 Trace Ion Detection is OFF.

 EMISSION    :      34.610
 ENERGY      :      69.922
 REPELLER    :      26.605
 IONFOCUS    :      78.769
 ENTRANCE_LE :      22.000
 EMVOLTS     :    1129.412
                               Actual EMV  :    1258.82
                               GAIN FACTOR :       1.03
 AMUGAIN     :    1732.000
 AMUOFFSET   :     121.063
 FILAMENT    :       1.000
 DCPOLARITY  :       0.000
 ENTLENSOFFS :      17.067
 MASSGAIN    :    -718.000   
 MASSOFFSET  :     -36.000   

                           END OF TUNE PARAMETERS
                      ------------------------------------



                                            END OF INSTRUMENT CONTROL PARAMETERS
                                            ------------------------------------