                              INSTRUMENT CONTROL PARAMETERS:    1
                              -----------------------------------

   C:\msdchem\1\METHODS\OPI23.M
      Wed Oct 29 09:26:20 2014

Control Information
------- -----------

Sample Inlet      :  GC
Injection Source  :  GC ALS
Mass Spectrometer :  Enabled


 No Sample Prep method has been assigned to this method.

Oven
Equilibration Time                           0,5 min
Max Temperature                              324 degrees C
Slow Fan                                     Disabled
Oven Program                                 On
    115 C for 3 min
    then 15 C/min to 280 C for 9 min
Run Time                                     23 min




Front Injector
Syringe Size                                 10 ?L
Injection Volume                             1 ?L
Solvent A Washes (PreInj)                    2
Solvent A Washes (PostInj)                   6
Solvent A Volume                             8 ?L
Solvent B Washes (PreInj)                    2
Solvent B Washes (PostInj)                   6
Solvent B Volume                             8 ?L
Sample Washes                                0
Sample Wash Volume                           8 ?L
Sample Pumps                                 2
Dwell Time (PreInj)                          0 min
Dwell Time (PostInj)                         0 min
Solvent Wash Draw Speed                      300 ?L/min
Solvent Wash Dispense Speed                  6000 ?L/min
Sample Wash Draw Speed                       300 ?L/min
Sample Wash Dispense Speed                   6000 ?L/min
Injection Dispense Speed                     6000 ?L/min
Viscosity Delay                              0 sec
Sample Depth                                 Disabled
Injection Type                               Standard
L1 Airgap                                    0,2 ?L


Sample Overlap
Sample overlap is not enabled



Front SSZ Inlet He
Mode                                         Splitless
Heater                                       On    270 C
Pressure                                     On    10,712 psi
Total Flow                                   On    11,501 mL/min
Septum Purge Flow                            On    1,0506 mL/min
Gas Saver                                    Off
Purge Flow to Split Vent                     10 mL/min at 0,3 min


Thermal Aux 1 (MSD Transfer Line)
Heater                                       On
Temperature Program                          On
    280 C for 0 min
Run Time                                     23 min


Column #1
Agilent 19091S-433: 2468,09280
HP-5MS  5% Phenyl Methyl Silox
325 C: 30 m x 250 ?m x 0,25 ?m
In: Front SSZ Inlet He
Out: Vacuum

(Initial)                                    115 C
Pressure                                     10,712 psi
Flow                                         0,95 mL/min
Average Velocity                             36,579 cm/sec
Holdup Time                                  1,3669 min
Flow Program                                 On
    0,95 mL/min for 0 min
Run Time                                     23 min



Signals
Signal #1: Test Plot                         Save Off
                                             50 Hz
Signal #2: Test Plot                         Save Off
                                             50 Hz
Signal #3: Test Plot                         Save Off
                                             50 Hz
Signal #4: Test Plot                         Save Off
                                             50 Hz

                                MS ACQUISITION PARAMETERS


General Information
------- -----------

Tune File                : atune.u
Acquistion Mode          : Scan


MS Information
-- -----------

Solvent Delay            : 3.00 min

EMV Mode                 : Relative
Relative Voltage         : 0
Resulting EM Voltage     : 776

[Scan Parameters]

Low Mass                 : 50.0
High Mass                : 650.0
Threshold                : 0
Sample #                 : 2       A/D Samples    4
Plot 2 low mass          : 50.0
Plot 2 high mass         : 550.0

[MSZones]

MS Source                : 230 C   maximum 250 C
MS Quad                  : 150 C   maximum 200 C


                             END OF MS ACQUISITION PARAMETERS


                              TUNE PARAMETERS for SN: US13321A04
                        -----------------------------

 Trace Ion Detection is OFF.

 EMISSION    :      34.610
 ENERGY      :      69.922
 REPELLER    :      25.600
 IONFOCUS    :      90.157
 ENTRANCE_LE :      25.500
 EMVOLTS     :     776.471
                               Actual EMV  :    776.471
                               GAIN FACTOR :       0.07
 AMUGAIN     :    2020.000
 AMUOFFSET   :     120.438
 FILAMENT    :       1.000
 DCPOLARITY  :       0.000
 ENTLENSOFFS :      18.824
 MASSGAIN    :    -660.000   
 MASSOFFSET  :     -38.000   

                           END OF TUNE PARAMETERS
                      ------------------------------------



                              END OF INSTRUMENT CONTROL PARAMETERS
                              ------------------------------------