                           INSTRUMENT CONTROL PARAMETERS:    7890-TOX
                           ------------------------------------------

   C:\MSDCHEM\1\METHODS\FT_Acquisition.M
      Wed Feb 18 11:32:30 2015

Control Information
------- -----------

Sample Inlet      :  GC
Injection Source  :  GC ALS
Mass Spectrometer :  Enabled


 No Sample Prep method has been assigned to this method.

Oven
Equilibration Time                           0.5 min
Max Temperature                              325 degrees C
Slow Fan                                     Disabled
Oven Program                                 On
    100 C for 0.25 min
    then 40 C/min to 325 C for 1.25 min
Run Time                                     7.125 min
1 min (Post Run)                             325 C
Cryo                                         Off

Front Injector
Syringe Size                                 10 L
Injection Volume                             1 L
Solvent A Washes (PreInj)                    2
Solvent A Washes (PostInj)                   8
Solvent A Volume                             8 L
Solvent B Washes (PreInj)                    0
Solvent B Washes (PostInj)                   8
Solvent B Volume                             8 L
Sample Washes                                3
Sample Wash Volume                           1 L
Sample Pumps                                 6
Dwell Time (PreInj)                          0 min
Dwell Time (PostInj)                         0 min
Solvent Wash Draw Speed                      300 L/min
Solvent Wash Dispense Speed                  6000 L/min
Sample Wash Draw Speed                       300 L/min
Sample Wash Dispense Speed                   6000 L/min
Injection Dispense Speed                     6000 L/min
Viscosity Delay                              0 sec
Sample Depth                                 Disabled
Injection Type                               Standard
L1 Airgap                                    0.2 L

Barcode Reader
Barcode heater                               Disabled
Barcode mixer                                Disabled

Sample Overlap
Sample overlap is not enabled

Front SS Inlet He
Mode                                         Splitless
Heater                                       On    280 C
Pressure                                     On    34.664 psi
Total Flow                                   On    59.586 mL/min
Septum Purge Flow                            On    3 mL/min
Gas Saver                                    On    20 mL/min After 2 min
Purge Flow to Split Vent                     50 mL/min at 0.4 min

Thermal Aux 2 (MSD Transfer Line)
Heater                                       On
Temperature Program                          On
    300 C for 0 min
Run Time                                     7.125 min

Column #1
J&W 122-5512DB-5ms
325 C: 15 m x 250 m x 0.25 m
In: Front SS Inlet He
Out: Aux EPC 1

(Initial)                                    100 C
Pressure                                     34.664 psi
Flow                                         6.5858 mL/min
Average Velocity                             113.86 cm/sec
Holdup Time                                  0.21957 min
Pressure Program                             On
    34.664 psi for 0 min
Run Time                                     7.125 min
1 min (Post Run)                             1 psi

Column #2
Siltek Treated FSSiltek Treated FS
350 C: 0.89 m x 180 m x 0 m
Main Segment Heated By Oven
  outSeg Heated By Thermal Aux 2: 0.17 m x 120 m x 0 m
In: Aux EPC 1 He
Out: Vacuum

(Initial)                                    100 C
Pressure                                     3.8 psi
Flow                                         1.6435 mL/min
Average Velocity                             117.5 cm/sec
Holdup Time                                  0.012624 min
Pressure Program                             On
    3.8 psi for 0 min
Run Time                                     7.125 min
1 min (Post Run)                             75 psi

Column #3
Siltek Treated FSSiltek Treated FS
350 C: 0.35 m x 180 m x 0 m
In: Aux EPC 1 He
Out: Front Detector NPD

(Initial)                                    100 C
Pressure                                     3.8 psi
Flow                                         4.605 mL/min
Average Velocity                             332.81 cm/sec
Holdup Time                                  0.0017528 min
Pressure Program                             On
    3.8 psi for 0 min
Run Time                                     7.125 min
1 min (Post Run)                             75 psi

Front Detector NPD
Heater                                       Off
H2 Flow                                      Off
Air Flow                                     Off
Makeup Flow                                  On    6.395 mL/min
Const Col + Makeup                           On    11 mL/min
Bead                                         Off
Front Detector
Signal 1 Type                                NPD
Maximum Bead Voltage                         1.1 V
Blos Bead                                    Yes
Dry Bead                                     Yes
Auto Adjust Bead                             Yes

Valve 1
Other                                        Off

Aux EPC 1 He: Supplies Column 2

Aux EPC 2 N2
Pressure Program                             Off
    1.5 psi for 0 min
Run Time                                     7.125 min

Aux EPC 3 N2
Pressure Program                             Off
    10 psi for 0 min
Run Time                                     7.125 min

Signals
Signal #1: Front Signal                      Save On
                                             10 Hz

Signal #2: Test Plot                         Save Off
                                             50 Hz

Signal #3: Test Plot                         Save Off
                                             50 Hz

Signal #4: Test Plot                         Save Off
                                             50 Hz

Run Time Events
  Time (min)    Event                          Position                       Setpoint
           0    Valve                          Valve 1                        On
        0.75    Valve                          Valve 1                        Off

                                MS ACQUISITION PARAMETERS


General Information
------- -----------

Tune File                : atune.u
Acquistion Mode          : Scan


MS Information
-- -----------

Solvent Delay            : 0.70 min

EMV Mode                 : Relative
Relative Voltage         : 0
Resulting EM Voltage     : 1482

[Scan Parameters]

Low Mass                 : 40.0
High Mass                : 570.0
Threshold                : 0
Sample #                 : 1       A/D Samples    2
Plot 2 low mass          : 50.0
Plot 2 high mass         : 550.0

[MSZones]

MS Source                : 300 C   maximum 320 C
MS Quad                  : 180 C   maximum 200 C


                             END OF MS ACQUISITION PARAMETERS


                              TUNE PARAMETERS for SN: US13123A08
                        -----------------------------

 Trace Ion Detection is OFF.

 EMISSION    :      34.610
 ENERGY      :      69.922
 REPELLER    :      14.710
 IONFOCUS    :      90.157
 ENTRANCE_LE :      35.000
 EMVOLTS     :    1482.353
                               Actual EMV  :    1482.35
                               GAIN FACTOR :       2.37
 AMUGAIN     :    1629.000
 AMUOFFSET   :     121.313
 FILAMENT    :       2.000
 DCPOLARITY  :       1.000
 ENTLENSOFFS :      17.318
 MASSGAIN    :    -875.000   
 MASSOFFSET  :     -37.000   

                           END OF TUNE PARAMETERS
                      ------------------------------------



                              END OF INSTRUMENT CONTROL PARAMETERS
                              ------------------------------------