                                         INSTRUMENT CONTROL PARAMETERS:    GC-MSD
                                         ----------------------------------------

   C:\MSDCHEM\1\METHODS\UNIVERSAL_EKC_ALP1.M
      Thu Jul 06 22:34:58 2017

Control Information
------- -----------

Sample Inlet      :  GC
Injection Source  :  GC ALS
Mass Spectrometer :  Enabled


 No Sample Prep method has been assigned to this method.

Oven
Equilibration Time                           0.5 min
Max Temperature                              425 degrees C
Slow Fan                                     Disabled
Oven Program                                 On
    60 C for 1 min
    then 15 C/min to 300 C for 20 min
Run Time                                     37 min
3.5 min (Post Run)                           320 C




Front Injector
Syringe Size                                 10 ?L
Injection Volume                             1 ?L
Solvent A Washes (PreInj)                    5
Solvent A Washes (PostInj)                   1
Solvent A Volume                             8 ?L
Solvent B Washes (PreInj)                    0
Solvent B Washes (PostInj)                   0
Solvent B Volume                             8 ?L
Sample Washes                                5
Sample Wash Volume                           8 ?L
Sample Pumps                                 6
Dwell Time (PreInj)                          0 min
Dwell Time (PostInj)                         0 min
Solvent Wash Draw Speed                      300 ?L/min
Solvent Wash Dispense Speed                  6000 ?L/min
Sample Wash Draw Speed                       300 ?L/min
Sample Wash Dispense Speed                   6000 ?L/min
Injection Dispense Speed                     6000 ?L/min
Viscosity Delay                              0 sec
Sample Depth                                 Disabled
Injection Type                               Standard
L1 Airgap                                    0.2 ?L


Sample Overlap
Sample overlap is not enabled



Front SSZ Inlet He
Mode                                         Splitless
Heater                                       On    250 C
Pressure                                     On    8.2317 psi
Total Flow                                   On    52.337 mL/min
Septum Purge Flow                            On    1.3368 mL/min
Gas Saver                                    On    20 mL/min After 2 min
Purge Flow to Split Vent                     50 mL/min at 0.5 min


Thermal Aux 1 {MSD Transfer Line}
Heater                                       On
Temperature Program                          On
    290 C for 0 min
Run Time                                     37 min


Column #1
Agilent 19091S-433: 2351.50726
HP-5MS  5% Phenyl Methyl Siloxane
325 C: 30 m x 250 ?m x 0.25 ?m
In: Front SSZ Inlet He
Out: Vacuum

(Initial)                                    60 C
Pressure                                     8.2317 psi
Flow                                         1 mL/min
Average Velocity                             36.623 cm/sec
Holdup Time                                  1.3653 min
Flow Program                                 On
    1 mL/min for 0 min
Run Time                                     37 min
3.5 min (Post Run)                           0.5 mL/min



Signals
 Test Plot                                   Save Off
                                             50 Hz
 Test Plot                                   Save Off
                                             50 Hz
 Test Plot                                   Save Off
                                             50 Hz
 Test Plot                                   Save Off
                                             50 Hz

                                MS ACQUISITION PARAMETERS


General Information
------- -----------

Tune File                : ATUNE.U
Acquistion Mode          : Scan


MS Information
-- -----------

Solvent Delay            : 4.30 min

EMV Mode                 : Relative
Relative Voltage         : 0
Resulting EM Voltage     : 1871

[Scan Parameters]

Low Mass                 : 42.0
High Mass                : 700.0
Threshold                : 150
Sample #                 : 2       A/D Samples    4
Plot 1 low mass          : 50.0
Plot 1 high mass         : 550.0
Plot 2 low mass          : 50.0
Plot 2 high mass         : 650.0

[MSZones]

MS Source                : 230 C   maximum 250 C
MS Quad                  : 150 C   maximum 200 C


                             END OF MS ACQUISITION PARAMETERS


                              TUNE PARAMETERS for SN: US000910MC
                        -----------------------------

 Trace Ion Detection is OFF.

 EMISSION    :      34.610
 ENERGY      :      69.922
 REPELLER    :      24.427
 IONFOCUS    :      79.718
 ENTRANCE_LE :      19.000
 EMVOLTS     :    1870.588
                               Actual EMV  :    1870.59
                               GAIN FACTOR :       0.26
 AMUGAIN     :    3162.000
 AMUOFFSET   :     120.875
 FILAMENT    :       1.000
 DCPOLARITY  :       0.000
 ENTLENSOFFS :      17.067
 MASSGAIN    :     -29.000   
 MASSOFFSET  :     -40.000   

                           END OF TUNE PARAMETERS
                      ------------------------------------



                                           END OF INSTRUMENT CONTROL PARAMETERS
                                           ------------------------------------